Autoclave Black Dragon 12 Litres Class B For Tattoo

£1,876.88

Autoclave Black Dragon 12 Litres Class B For Tattoo

Autoclave Black Dragon 12 liters and class B with finishes in black color for Tattoo studios.

  • Shipping: Free Shipping
  • Delivery Time: 5 – 10 Days
Quantity:
View List
SKU: QRD-922-STE-B12DNE.
Share:

Description

Autoclave Black Dragon 12 Litres Class B For Tattoo

Autoclave Black Dragon 12 liters Class B for tattoo studios.

Programmes:

 

Programmes Temperature Pressure Sterilisation time Total time Type Max. load Max. load per tray
Solid 134 0C 210 kPa 4 min 14-30 min Solid unwrapped 4 Kg 1.2 Kg
1210C 110 kPa 20 min 30-45 min
Wrapped 134 0C 210 kPa 4 min 30-45 min Solid unwrapped 3.5 Kg 1.1 Kg
121 0C 110 kPa 20 min 35-55 min Solid or hollow simple wrapped 3.5 Kg 1.1 Kg
Liquid 134 0C 210 kPa 10 min 30-55 min Liquid 0.80 kg 0.25 kg
121 0C 110 kPa 30 min 35-60 min
Textile 134 0C 210 kPa 8 min  

30-50 min

Porous unwrapped 1 Kg 0.3 Kg
Porous simple wrapped 0.75 Kg 0.2 Kg
121 0C 110 kPa 30 min 40-60 min Porous double wrapped 0.5 Kg 0.15 Kg
Hollow simple wrapped 3.5 Kg 1 Kg
Solid or hollow double wrapped 1.5 Kg 0.5 Kg
Prion 134 0C 210 kPa 18 min 30-50 min Porous unwrapped 0.1 Kg 0.3 Kg
Porous simple wrapped 0.75 Kg 0.2 Kg
Porous double wrapped 0.5 Kg 0.15 Kg
Hollow simple wrapped 3.5 Kg 1 Kg
Solid or hollow double wrapped 1.5 Kg 0.5 Kg
B&D test 134 0C 210 kPa 3.5 min 22-35 min
Helix test 134 0C 210 kPa 3.5 min 22-35 min
Vacuum test 18-20 min

Safety:

  • A cycle will not start unless the door is firmly closed.
  • An automated system with a double hydraulic locking device prevents the door from opening while the chamber is pressurized.
  • The safety valves prevent overpressure in the generator and in the chamber.
  • A safety thermostat prevents overheating in the chamber and in the generator.
  • An automatic safety lock prevents accidental opening of the door during the sterilisation. A power protector automatically cuts off power in case of a short circuit or if the power supply is not very stable.
  • The failure alarm indicates a cycle failure and provides an error code.
  • The door alarm indicates that the door is not properly closed.
  • The low water alarm indicates when the water tank is empty or too full.

 Technical features:

  • Power supply: 220-240V; 50/60Hz; 10A
  • Chamber: 200 x 360 mm
  • Breaker: F16A / 400V
  • Nominal power: 2200VA
  • Sterilisation temperature: 121 0C / 1340C
  • Capacity of the distilled water tank: 2.5 L
  • Working temperature: 5 0C / 40 0C
  • Working relative humidity: Max. 80%, non-condensing
  • Overall dimensions: 414 x 365 x 570 mm
  • Net weight: 51 Kg
  • Max. noise level: <70 dB
  • Atmospheric pressure: 76 / 106 kPa

Components:

  • Distilled water tank
  • LCD display
  • Control panel
  • Main power switch
  • Drain connector (distilled and used water tank)
  • USB port
  • Safety valve
  • Ventilation grid
  • Circuit breaker
  • Power cable
  • Rating plate

Accessories included:

  • Steriliser
  • USB
  • 3 instrument trays
  • Tray rack
  • Tray holder
  • Door adjustment tool
  • 2 draining hoses
  • Door gasket
  • User manual

Standards:

  • 93/42/EEC Directive on Medical Devices.
  • 97/23/EEC Directive on Pressure Equipment.
  • EN 13060 Small Steam Sterilisers.
  • EN 61326, EN 61000 Electromagnetic Compatibility.
  • EN 61010-1, UL 61010-1 Safety requirements.
  • EN 61010-2-040, IEC 61010-2-040 Specific requirements for steam sterilisers used for the treatment of medical materials.

In the UK this product needs to be inspected and certified annually. Oras Medical doesn´t offer this service and you will need to find your own local technician who can do this.

AUTOCLAVE – step by step:

  • Open the door, take the tools and accessories that are within the sterilisation chamber, remove the wrapper and clean them.
  • Connect the power cord to a suitable power source.
  • Connect the printer (optional. It is sold separately, ref. QRD-922-PRINTER04.
  • Switch on: The main switch is located on the right bottom area in the front panel.
  • Once activated, the LCD screen is on, where basic operation icons such as the position of the door, the water level, the sterilisation programme, date, time, etc. appear.
  • Fill the tank with distilled water.
  • Remove the top lid and fill, if you hear a signal, it means that you exceeded the permitted level of water in the tank, please stop immediately and drain the amount of water necessary for the signal off.

Preparation of instruments:

  • Place instruments made of different materials in different trays, however, take care to separate them before sterilisation.
  • If the instruments are not stainless steel, put some sterilisation paper between the tray and the instruments.
  • Do not allow direct contact between instruments of different materials.
  • Verify that all instruments are in correct position.
  • Place instruments such as lenses, containers, tubes, etc. inverted, so that water does not stagnate within them.
  • Do not overload the trays beyond their limit.
  • Do not overlap the trays on top of each other, or put them in direct contact with the wall of the sterilisation chamber.
  • Do not use metal clips or pins, this may impair the operation of the steriliser.
  • Wrap the instruments one by one. If you need to wrap several instruments together, make sure that they are made of the same material.
  • Seal the pouch with special adhesive tape for sterilisation or use a heat sealer.
  • Make sure that the pouch is properly positioned within the chamber on the trays (resting on the plastic part).

Choose the sterilisation programme.

Start the sterilisation cycle.

  • After selecting the sterilisation programme, insert instruments into the chamber on the trays, using the supplied plastic handle.
  • Once the instruments are placed within the chamber, close the door by turning the knob.
  • Caution: make sure to close the door, otherwise, the steriliser displays an alarm and can not start or the programme stops during the cycle.

Start the sterilisation programme.

  • Press the start button, then the steriliser starts operating for approximately 30-75 minutes.

Sterilisation cycle finished.

  • After finishing the sterilisation cycle, the printer (not included*) will print the full report automatically and the data will be saved in the USB memory (.txt format).
  • After the pressure drops to zero, you can open the door and remove the instruments. The steriliser alerts by a beep once the sterilisation cycle is completed.
  • Caution: Use the supplied plastic handle for supporting trays when you take out the instruments.

IMPORTANT: Do not reuse used water.

Installation:

  • There must be at least 10 cm of free space around the steriliser, 25 cm at the top, and enough room to open the door.
  • The place where the steriliser is used must have proper ventilation.
  • The steriliser must be placed on a stable surface and at an appropriate height for handling.
  • Do not cover or block the lateral outlets or the outlet air grid of the condenser fan.
  • Do not place the steriliser near water sources.
  • Keep away from heat sources.

Example of the printed report:

================================
Programme: WRAPPED

Temperature: 134C
Pressure: 206.0 kPa
Drying time: 08min
Sterilisation time: 4.0Min
——————————–
Time Temp. pressure
Start 12:28:17 089.0C
T1: 12:31:32 087.1C -075.0kPa
T2: 12:33:43 110.2C 052.0kPa
T3: 12:36:37 088.9C -080.0kPa
T4: 12:39:20 114.7C 053.7kPa
T5: 12:43:37 087.9C -080.0kPa
T6: 12:50:40 134.8C 206.0kPa
TS: 134.7C 209.5kPa
Max. Temperature: 135.2C
Min. Temperature: 134.3C
Max. Pressure: 214.0kPa
Min. Pressure: 204.9kPa
T7: 12:54:39 134.4C 211.4kPa
T8: 12:57:36 102.1C -060.0kPa
T9: 12:59:54 098.2C -060.0kPa
End 13:04:07 102.4C
——————————–
Cycle No .: 00017
Result: success
Date: 07/06/2014
SN: E54723
operator

  • Free Shipping: We offer free shipping for all our products. This means the price you see on this page is the price you will pay at checkout. No additional cost will be added.
  • Processing and Delivery: Most orders are processed within 24 hours if in stock. Delivery time for most orders is 7 – 14 business days. However, some of our products especially pillows, cushions and wedges are delivered with 5 business days if they are in stock. Please check individual product page for delivery time.
  • Out of Stock Orders: Sometimes, products can be out of stock even when they show they are in stock on our website. If you place an order and the product is out of stock, we will notify you immediately and inform you how long it would take for the item to be back in stock and shipped. You will have the option to either wait or have your payment refunded.
  • Possible Delayed Shipping: On some products on our website, we have noted that shipping may be delayed. Please ask us before purchasing such products to ensure they are in stock.