Vital Signs Monitor ECG SpO2 NIBP RESP TEMP and CO2 Capnography

This vital signs monitor is used in labs and hospitals or clinics, where monitoring systems are needed. It provides fast and reliable results for both adults and newborn patients.

FEATURES:

Heart/pulse rate: it is measured with the parameters ECG, oximetry, and non-invasive blood pressure (NIBP).

Electrocardiography (ECG):

  • The monitor provides continuous processing of 5-lead ECG, with standard lead selections, and filtering from electrocautery discharge.
  • The user can view up to 3 waveform channels simultaneously.

Oximetry: The oximetry parameter provides the continuous non-invasive monitoring of oxygen saturation (%SpO2) in the blood and pulse rate (PR).

Non-invasive blood pressure (NIBP):

  • The non-invasive blood pressure (NIBP) parameter provides systolic, diastolic, and mean arterial blood pressure values, and heart rate.
  • NIBP measurements can be made in automatic, manual, or STAT modes.

Respiratory rate (RR): The monitor provides respiration rate and Resp waveform by measuring the thoracic impedance between two ECG electrodes on the patient’s chest.

Temperature (TEMP): Two independent channels of temperature (T1 and T2) monitoring are available

CO2:

  • The monitor determines CO2 concentration in the breathing gases by measuring the amount of light absorbed by these gases.
  • EtCO2 is displayed as a numerical value in millimeters of mercury (mmHg), percent (%), or kilopascals (kPa).
  • In addition, a CO2 waveform (capnogram) may be displayed which is a valuable clinical tool that can be used to assess patient airway integrity and proper endotracheal tube placement.
  • Respiration rate is calculated by measuring the time interval between detected breaths.

Display:

  • The monitor has a high-resolution, high-contrast, color LCD display.
  • It provides a continuous, real-time display of up to four waveforms.
  • It also shows measured values, chronological data, measurement trends, alarm limits, and patient information.

Internal battery:

  • The installed internal rechargeable battery is intended primarily for backup and switch-over use.
  • Typical battery life is 2 to 5 years depending on usage.
  • A fully charged battery will last 2 to 3.5 hours, depending on monitor usage.

TECHNICAL SPECIFICATIONS:

Display:

  • 7-inch diagonal high-resolution TFT (Thin Film Transistor) Active Matrix LCD
  • Resolution: 800 x 480 pixels.

Indicators:

  • Work Status LED
  • AC Power LED
  • Battery Charge LED
  • Battery Supply LED
  • Alarm Silence LED

Alarm volume: 45dBA to 85 dBA at 1 meter distance (adjustable)

ECG:

  • Heart rate range: 20-350 bpm
  • Heart rate accuracy: 2 bpm o ± 2% ((whichever is greater)
  • QRS detection range: 0.5 to 5 mV
  • Pace pulse detection: Amplitude: 2 mV to 700 mV
  • Detection duration: 0.1 – 2.0
  • Alarm ranges heart rate:
    • High: 20-350 bpm and off
    • Low: 20-350 bpm and off
  • Heart rate averaging: Fixed 8 second averaging
  • Lead selection: I, II, III, V, aVR, aVL, or aVF (5 lead)
  • Display gain settings: X1/4, X1/2, X1, X2, X4
  • Input range: -5.0 mV to +5.0 mV
  • Frequency response: 0.05 Hz to 40 Hz
  • Input impedance: > 5 Mohms differential, as required and tested per ANSI/AAMI EC-13.
  • Leakage: < 10 uA
  • Patient isolation: > 4000 VCA
  • Display waveform: 120 Hz; 6.25, 12.5, 25, or 50 mm/s
  • Update rate digits: 1 Hz

SpO2:

  • SpO2 range: 0-100%  Functional Saturation
  • SpO2 accuracy:
    • ± 2% @ 70-100%
    • <70% unspecified
  • Pulse rate range: 20-350 bpm
  • Pulse rate accuracy: ± 2 bpm o ± 2% (whichever is greater)
  • SpO2 alarm ranges:
    • High: 50 – -100% and off
    • Low: 50 – -100% and off
  • Calibration: Factory calibrated over the range 50% to 100% SpO2 using human blood samples to functional saturation.

NIBP:

Blood Pressure Measuring

  • Method of measuring: Oscillometric with step-down deflation
  • Range: Systolic: 40 to 270 mmHg
  • Mean arterial: 30 to 220 mmHg
  • Diastolic: 20 to 200 mmHg
  • Pulse: 25 to 300 bpm
  • NIBP accuracy:  Algorithm based on a human algorithm that meets or exceeds accuracy requirements of ANSI / AAMI SP10:1992 and 2002 standards for non-invasive blood pressure using the oscillometric method.

Inflation Pressure Settings

  • Measurement time: 30 to 50 seconds (typical), 120 seconds maximum.
  • Default Inflation Pressure:
    • 120 mmHg – Adult
    • 100 mmHg – Pediatric
    • 90 mmHg – Neonatal
  • Calibration: Factory calibrated
  • AUTO interval times: 2, 3, 5, 10, or 30 minutes, or 1, 2 hours 20-260 (in 1 mmHg steps), and off
  • Alarm range: 25- 250 bpm, ± 2% or ± 3 bpm ((whichever is greater)
  • Pulse rate accuracy: 251-300 bpm, ± 5%

Respiratory rate (RESP):

  • Range: 0-120 breaths per minute (bpm)
  • Accuracy: ±1 bpm
  • Resolution: 1 bpm
  • RESP alarm range:
    • High: 0-120 bpm (1 bpm steps) and off
    • Low: 0-120 bpm (1 bpm steps) and off

Temperature (TEMP):

  • Channel: Two
  • Range: 25-45ºC
  • Accuracy: ± 0.2ºC plus the temperature sensor tolerance
  • Resolution: 0.1ºC
  • TEMP alarm range:
    • High: 35.5-43.5ºC and off in 0.1 increments
    • Low: 35.5-43.5ºC and off in 0.1 increments

CO2:

  • Sampling mode: Sidestream
  • Measuring parameters: Respiration rate, EtCO2 and InsCO2.
  • CO2 warm-up time: 10 seconds.
    • Measurement range CO2: 0~150mmHg
    • Respiration rate: 2~150bpm
  • Accuracy:
    • 0~40mmHg ±2mmHg
    • 41~150mmHg ±10% of reading
  • Resolution: 0.1mmHg
  • Flow rate: 50 ml/min±10 ml/min

Supply requirements: AC input: 100 to 240 V, 50/60 Hz

Dimensions:

  • Width: 300 mm.
  • Length: 180 mm.
  • Height: 130 mm.
  • Unit weight: 2 kg. approx.
  • Total weight: 3.6 Kg. approx.

Environmental protection:

  • Temperature:
    • 0 to 50ºC (operation)
    •  -40 to 75ºC (storage)
  • Humidity:
    • 15 to 95% (operation)
    • 10 to 95% (storage)

Classification:

  • Type of protection (against electric shock): CLASS I (internally powered)
  • Mode of operation: Continuous
  • Degree of protection (against ingress of liquids): IPX1, drip-proof
  • Degree of mobility: Portable
  • Degree of protection (against electric shock): Type CF
  • Safety requirements: EN60601-1:2002

INCLUDES:

  • Vital signs monitor
  • ECG cable 5 leads
  • Temperature probe
  • Reusable finger oximetry probe for adults
  • NIBP tube with cuff adult 27-35 cm
  • CO2 accessories
  • Internal battery
  • Power cable
  • User manual

CERTIFICATION:

  • Directive 93/42/EEC on Medical Devices.
  • Free Shipping: We offer free shipping for all our products. This means the price you see on this page is the price you will pay at checkout. No additional cost will be added.
  • Processing and Delivery: Most orders are processed within 24 hours if in stock. Delivery time for most orders is 7 – 14 business days. However, some of our products especially pillows, cushions and wedges are delivered with 5 business days if they are in stock. Please check individual product page for delivery time.
  • Out of Stock Orders: Sometimes, products can be out of stock even when they show they are in stock on our website. If you place an order and the product is out of stock, we will notify you immediately and inform you how long it would take for the item to be back in stock and shipped. You will have the option to either wait or have your payment refunded.
  • Possible Delayed Shipping: On some products on our website, we have noted that shipping may be delayed. Please ask us before purchasing such products to ensure they are in stock.