Ensure the highest standard of care for your animal patients with our Veterinary Vital Signs Monitor with CO₂ Capnography. Designed specifically for veterinary use, this advanced monitor delivers accurate, real-time readings of essential parameters, including ECG, SpO₂, NIBP, RESP, Temperature, and CO₂ to help you make quick, informed decisions during treatment or surgery. Compact, reliable, and easy to use, it’s the perfect solution for clinics, hospitals, and mobile veterinary practices seeking comprehensive monitoring in one powerful device.
The vital signs monitor is intended for use in special procedures in laboratories or in a veterinary clinic where veterinary surveillance systems are needed.
Features:
Heart / pulse rate: It measures with the parameters ECG, oximetry and noninvasive blood pressure (NIBP).
Electrocardiogram (ECG):
- The monitor provides the continuous process of 5 lead ECG, with standard derivation selection and filtering electrocautery discharge.
- You can display up to 3 channels of waveform simultaneously.
Oximetry: The oximetry parameter provides continuous noninvasive monitoring of oxygen saturation (% SpO2) in the arterial and pulse frequency (PR).
Noninvasive arterial pressure (NIBP):
- The noninvasive arterial pressure parameter (NIBP) provides values as systolic and diastolic blood pressure and average plus heart rate.
- NIBP measurements can be made automatically, manually or STAT.
Respiraty Rate (RR): The monitor provides respiratory rate and Resp wave form by measuring thoracic impedance between two ECG electrodes on the patient’s chest.
Temperature (TEMP): Includes two independent temperature control channels (T1 and T2).
CO2:
- The monitor determins the concentration of CO2 in respiratory gases by measuring the amount of light absorbed by these gases.
- EtCO2 is displayed as a numeric value in millimeters of mercury (mmHg), percentage (%) or kilopascals (kPa).
- Furthermore, a CO2 waveform (capnography) can be viewed, a valuable clinical tool which may be used to assess the integrity of the patient´s airway and proper placement of the endotracheal tube.
- The respiratory frequency is calculated by measuring the time interval between the detected breaths.
Monitor:
- The monitor has a colour LCD screen with high resolution and high contrast.
- It provides a continuous, real-time image with up to 4 wave forms.
- It also shows the measured values, historical data, measurement trends, alarm limits and patient information.
Internal battery:
- The internal rechargeable battery is primarily intended for backup and switching use.
- The expected life of the battery is 2-5 years, depending on its use.
- A fully charged battery will last 2 to 3.5 hours depending on the usage of the monitor.
You can select patient type:
- Horse
- Dog
- Cat
Technical specifications:
Display:
- 7 inches high resolution, active matrix flat screen (TFT: Thin Film Transistor).
- Resolution: 800 x 480 pixels.
Indicators:
- LED working status
- LED AC power
- LED battery charger
- LED battery supply
- LED alarm silence
Alarm volume: 45dBA to 85 dBA, at 1 metre distance (adjustable).
ECG:
- Heart rate range: 20-350 lpm
- Accuracy of heart rate: 2 lpm or ± 2% (whichever is greater)
- QRS detection range: 0,5 to 5 mV
- Pacemaker pulse detection: Amplitude: 2 mV to 700 mV
- Detection length: 0,1 – 2,0
- Alarm heart rate ranges:
- High: 20-350 lpm and off
- Low: 20-350 lpm and off
- Average heart rate: 8 seconds fixed as average
- Lead selection: I, II, III, V, aVR, aVL, or aVF (5-lead)
- Gain display settings: X 1/4, X1/2, X1, X2, X4
- Input range: -5,0 mV to +5,0 mV
- Frequency response: 0,05 Hz to 40 Hz
- Input impedance: Differential > 5 Mohms, as required and tested by ANSI/AAMI EC-13.
- Leakage: < 10 uA
- Isolation of patients: > 4000 VCA
- Waveform display: 120 Hz; 6.25, 12.5, 25, or 50 mm/s
- Frequency digits update: 1 Hz
SpO2:
- SpO2 range: 0-100% functional saturation
- SpO2 accuracy:
- 70-100% ± 2%
- <70% unspecified
- Pulse frequency range: 20-350 lpm
- Pulse frequency accuracy: ± 2 lpm or ± 2% (whichever is greater)
- SpO2 alarm range:
- High: 50 – -100% and off
- Low: 50 – -100% and off
- Calibration: Factory calibrated SpO2 range of 50% to 100% using human blood samples to a functional saturation.
NIBP:
- Blood pressure measurement
- Measurement method: Oscillometric with reducing deflation
- Range: Systolic: 40 a 270 mmHg
- Blood average: 30 to 220 mmHg
- Diastolic: 20 to 200 mmHg
- Pulse: 25 to 300 lpm
- NIBP accuracy: Algorithm based on human algorithm that meets or exceeds the accuracy requirements of standards ANSI / AAMI SP10:1992 and 2002 for non-invasive blood pressure using the oscillometric method.
- Inflation pressure setting.
- Measurement time: 30 to 50 seconds (typical), 120 seconds maximum
- Inflation pressure preset:
- 200 mmHg – Cat
- 150 mmHg – Dog
- 120 mmHg – Horse
- Calibration: Factory calibrated
- AUTO time interval: 2, 3, 5, 10, or 30 minutes, or 1, 2 hours 20-260 (in steps of 1 mmHg), and off
- Alarm range: 25- 250 lpm, ± 2% or ± 3 lpm (whichever is greater)
- Pulse frequency accuracy: 251-300 lpm, ± 5%
Respiratory rate (RESP):
- Range: 0-120 breaths per minute (rpm)
- Accuracy: ±1 rpm
- Resolution: 1 rpm
- RESP alarm range:
- High: 0-120 rpm (1 rpm steps) and off
- Low: 0-120 rpm (1 rpm steps) and off
Temperature (TEMP):
- Channel: Two
- Range: 25-45ºC
- Accuracy: ± 0.2ºC plus tolerance of the temperature sensor
- Resolution: 0.1ºC
- TEMP alarm range:
- High: 35.5-43.5ºC and deactivated in 0.1 increments
- Low: 35.5-43.5ºC and deactivated in 0.1 increments
CO2:
- Sampling mode: Secondary
- Measurements parameters: Respiratory rate, EtCO2 and InsCO2.
- CO2 warm up time: 10 seconds.
- Measuring range:
- CO2: 0~150mmHg
- Respiratory rate: 2~150bpm
- Accuracy:
- 0~40mmHg ±2mmHg
- 41~150mmHg ±10% reading
- Resolution: 0.1mmHg
- Flow rate: 50 ml/min±10 ml/min
Power requirements: AC input: 100 to 240 V, 50/60 Hz
Dimensions:
- Width: 300 mm.
- Length: 180 mm.
- Height: 130 mm.
- Weight equipment: 2 kg approx.
- Weight total: 3.6 kg approx.
Environmental protection:
- Temperature:
- From 0 to 50 0C (operation)
- From -40 to 75 0C (storage)
- Humidity:
- From 15 to 95% (operation)
- From 10 to 95% (storage)
Equipment classification:
- Protection type (againt electrocutions): CLASS I (internal power supply)
- Operation mode: Continuous
- Degree of protection (against liquid ingress): IPX1, drip proof
- Degree of mobility: Portable
- Degree of protection (against electrocutions): Type CF
- Safety requirements: EN60601-1:2002
Includes:
- Veterinarian vital signs monitor
- Extension cord SpO2 + 2 oximetry sensors
- Cable, ECG, 5-lead + 5 clamps
- NIBP tube with:
- NIBP cuff, large, 7-13 cm (horses)
- NIBP cuff, medium, 6-11 cm (dogs)
- NIBP cuff, small, 4-8 cm (cats)
- Rectal temperature probe
- Accessories for CO2
- Internal battery
- Power cable
- User manual
Certification:
- Directive CE 93/42 on Medical Products.

















Penelope Stuart (Verified Customer) –
This monitor provides cost-effective SpO₂ and CO₂ monitoring with accuracy and durability. It’s designed for both intubated and non-intubated patients, ensuring effective capnography monitoring for continuous long-term use. The device features a 5.7-inch high-resolution display, lightweight and portable design, and a built-in rechargeable lithium-ion battery for up to 10 hours of continuous operation.